HP ML10 V2 Server 2012 R2 Raid Rebuild 重建 RAID 1 – 1T * 2

第2棵硬碟壞掉 , 換了新硬碟 , Rebuilding 2個星期, 進度都在 0%。

答案是 : 要在開機時 , 某個畫面 按 F1 , 才會在開機後, 進行 Rebuild 的動作。

https://community.hpe.com/t5/ProLiant-Servers-ML-DL-SL/B110i-Array-not-rebuilding-Code-776-Ready-for-Recovery-is-queued/td-p/6878347#.YTXb389-WUl

https://homeservershow.com/forums/topic/11276-failed-drive-queued-for-rebuild/

HP Smart Array B110i SATA RAID Controller (v1.10) 2 Logical Drives
786-Slot 0 Drive Array Recovery Needed
The following disk drive(s) need Automatic Data Recovery (Rebuild):
Port 1I: Box 1: Bay 1
Select "F1" to continue with recovery of data to drive(s)
Select "F2" to continue without recovery of data to drive(s)
(RESUME = "F1" OR "F2" KEY)

press F1 now!

HP ML10 V2 Raid Rebuild 重建
HP ML10 V2 Raid Rebuild 重建
HP ML10 V2 Raid Rebuild 重建
HP ML10 V2 Raid Rebuild 重建
HP ML10 V2 Raid Rebuild 重建
HP ML10 V2 Raid Rebuild 重建
HP ML10 V2 Raid Rebuild 重建